PC-422R9

High acceleration life test box PC-R9 series

Remote network monitoring

Excellent box structure and materials

One click cleaning function of test box

Controller USB data output

Air FAST function (optional)

Details

Controller advantages

Programmable high-precision temperature and humidity controller

Compared with traditional HAST devices, the new controller is easier to operate due to the use of an interactive touch screen input system.

Remote control

Remote control can be achieved through the use of external terminal devices, enabling networked control of multiple machines and reducing the need for operator monitoring and operations.

High precision dual box design system (IEC60068-2-66)

The test box and steam generator are independent of each other

The separated testing system has the following advantages compared to a single container system:
.Reduce mutual interference between the test box and steam generator, completely avoiding condensation
.Having a larger testing capacity
.Has a wider humidity range (65% -100%)

Easy to operate/easy to connect

Electronic lock (button) and sliding tray

The electronic door lock system only requires pressing a button to open or close the door. Additionally, sliding the tray can open both the tray and the door simultaneously. In this way, users do not need to reach into the testing chamber to take out samples when the temperature is high just after the test is completed.

Simple wiring function

The bias terminal is installed on the inside of the door, which is very helpful for sample wiring.

Bias terminal

Each enclosure comes with 20 bias terminals as standard, with a maximum of 100 bias terminals available for installation in PC-422R9 and 60 bias terminals available for installation in PC-304R9.

The control mode can be selected according to the purpose

Two control modes

1. Unsaturated steam control for HAST and PCT

The unsaturated steam test mode allows the humidity to be set between 65% -100% RH without causing water droplets to condense. In addition, if it is a fixed value operation standard program function, it can be used to set the rise and fall rate and control the temperature. The test conditions specified by IEC60068-2-66, JISC0096, etc. can be met.

2. PTC saturation control

This mode is only used for wet saturated steam testing at 100% RH. Always maintain a 100% RH humidity state, also known as a wet saturation setting, which produces water droplets that condense and drip onto the sample.

The test can be conducted in the corresponding existing saturated pressure cooker.

The exhaust method can be selected according to the purpose

Three exhaust modes  

1. Slow cooling under constant humidity

After testing, the current humidity remains unchanged and slow cooling occurs.

2. Cooling to maintain humidity

After testing, the inside of the box is cooled by blowing air without exhausting until the pressure drops to 0 Pa to avoid the sample being damaged by pressure or blown dry by strong exhaust air. At the same time, this method of cooling is faster than natural cooling.

3. Strong exhaust

After testing, immediately open the exhaust valve to quickly release hot water and steam. This is equivalent to the testing done on a saturated pressure cooker.

Optional

HAST-NET RS232C interface

Control 16 HASTs simultaneously with one computer


Basket

PC-304R9:W172×D346×H30mm

PC-422R9:W252×D410×H30mm


Three layer tray

PC-304R9:W264×D350×H135mm

PC-422R9:W370×D412×H215mm


Pallet

Customizable


Recorder

Paper recorder
Paperless recorder

High voltage test wiring terminal

It can also be used in conjunction with ion migration devices for automatic measurement of insulation resistance


Bias terminal

Each box comes with 20 bias terminals as standard, up to 100 bias terminals can be installed in PC-422R9, and up to 60 bias terminals can be installed in PC-304R9


Water supply device for water injection tank

Pure water can be automatically supplied directly to the built-in water tank through the pipeline

    

High voltage terminal

Available at 1000V or 2000V     

         

Maximum heat dissipation value

50W


Temperature, humidity, and control range during the testing process

QQ截图20251231165630.jpg



Main parameters
ModelPC-304R9PC-422R9
SizeW710xD950xH1620mmW710xD950xH1620mm
Test box sizeΦ300D522(34.5L)Φ420D657(84.4L)
Effective box sizeΦ220D350(12L)Φ340D475(40L)
Net weight260 kg295 kg
Power supply1ΦAC220V/230V/240V 50/60Hz 2.3kW1ΦAC220V/230V/240V 50/60Hz 3.0kW
Heater capacitySteam generator 1.5kWSteam generator 1.5kW
Test box 0.6kWTest box 1.3kW
Operation ModeProgram mode and dependent mode
ProgramCan create 150 models in 1500 steps (maximum)
Test modeSaturated/Unsaturated
Temperature controlPID control/SCR control
Test temperature
Temperature range
105.0~151.4C(at 100%RH)105.0~133.3C(at 100%RH)
110.0~157.5C (at 85%RH)110.0~140.0C (at 85%RH)
118.0~162.5C (at 65%RH)118.0~150.0C (at 65%RH)
Temperature control accuracy土0.5°C
Distribution accuracy士0.5°C(at 100%RH)
1.0°C(at100%RH)
Humidity range65-100%RH
Humidity control accuracy士3% RH(at 85% RH)
Pressure range0.019~0.393MPa0.019 ~0.208MPa
Pressure vessel categorySmall pressure vessels
Test timeContinue for up to 500 hours
Time range1 minute -999 hours 59 minutes
Power failure protectionAbout 4 seconds
Time to reach rated temperatureApproximately 70 minutes (time from room temperature to 120C/85% RH)
Exhaust modeMode 1: Slow cooling at constant temperature Mode 2: Cooling mode to maintain humidity Mode 3: Strong exhaust
Bias end20 per box (125V total 30W)
Time signal terminal4
Emergency stop switchEquipped
BoxSUS316L stainless steel (electrolytic polishing)
Water supplyAutomatic supply from the water injection tank
Door systemMotor drive system with tray
Security Alert SystemOvertemperature protection, dry burning protection, overpressure protection, leakage protection, overpressure safety valve, temperature sensor, power-off protection, box door lock abnormal protection, water supply abnormal protection
Standard AccessoriesInlet pipe, drainage pipe, power cord, water supply tank, test basket, user manual

*The actual data is based on the assumption that the ambient temperature is normal indoor temperature and there are no samples inside the box. The power supply, voltage, and frequency mentioned above are fixed values